Krishna Shah, M. Optom.
Optometrist, Sankara Nethralaya, Chennai, India

Image: Rigid Gas Permeable Lens in Corneal Tear Repair Demonstrating Edge Lift
This case follows a 24-year-old male who sustained a significant corneal injury from a wooden stick. After surgery to repair the tear, Rigid Gas Permeable (RGP) contact lenses were fitted for visual rehabilitation. While RGP lenses offer sharper vision, they also present challenges, particularly edge lift. This occurs when the lens does not sit perfectly on the cornea, leading to misalignment. The case highlights the delicate balance between achieving an optimal fit and managing edge lift, with images demonstrating the complexities of lens fitting in corneal repair cases.